Skip to content
0 items in cart

Cart

Your cart is empty.

Expanded product image

Deye inverter family only; not the complete set

Solitec

Deye-based 15 kW set - Battery backup only

SKU: DY-PNG-0454

Price on request

Request a quote

Tell us what you need and our team will reply with a confirmed price and availability.

Product details

Description

Deye-based 15 kW set - Battery backup only

Industrial catalogue range · Battery backup

A proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.

Proposed specifications and contents

  • Inverter proposal: 1 × Deye SUN-15K-SG05LP3-EU-SM2; catalogue output class 15 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.
  • AC configuration: three-phase inverter family. Confirm the required site voltage/frequency and, for three-phase installations, each phase’s load and output limit.
  • PV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.
  • Storage proposal: 5 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 25.6 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery/inverter compatibility must be confirmed.
  • Balance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses/breakers, busbars and communication leads, AC isolation/protection, earthing and any required metering/monitoring.

Benefits and intended use

Prioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.

Consider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical/life-support or other safety-critical loads without a specialist design.

Minimum requirements before ordering

  • Provide an appliance/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 15 kW is not a promise of whole-site coverage.
  • Size the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 5-battery bank is not a guaranteed minimum for every application.
  • An approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.
  • A qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.

Expansion to match your requirements

  • For longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.
  • For solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.
  • For higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.

Quotation and exclusions

For sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.

Catalogue set reference: SET-15-24.

Manufacturer specification references: SE-G5.1 Pro-B battery; SG05LP3 inverter family. Confirm the supplied revision before ordering.

Choose a proposed configuration for quotation

These are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.

  • Essential backup: Assess the listed inverter/battery proposal against load watts, starting demand and required hours. No PV included. Request this profile by email
  • Longer backup: Request additional compatible storage sized for usable energy AND discharge current within inverter/BMS limits. Request this profile by email
  • Add solar charging: Request a compatible PV array, string design, mounting, cables, protection and installation. Request this profile by email

Request a Quote