{"product_id":"dy-png-0451","title":"Deye-based 12 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 12 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-12K-SG05LP3-EU-SM2; catalogue output class 12 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 12 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-12-21.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051114054,"sku":"DY-PNG-0451","price":65423.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_cfac16e1-b1d4-435f-8f05-b57b7637f182.png?v=1793340338","url":"https:\/\/xrosia-pg.com\/products\/dy-png-0451","provider":"Solitec PNG","version":"1.0","type":"link"}