{"title":"Solar Kits","description":null,"products":[{"product_id":"dy-png-0431","title":"Deye-based 3 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 3 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3K-SG04LP1-EU; catalogue output class 3 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 7 × third-party 550 W panels = 3.85 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-3-1.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856047968326,"sku":"DY-PNG-0431","price":37323.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_2f2ef44c-0200-4f98-a6f9-c426a17e7f76.png?v=1793340323"},{"product_id":"dy-png-0432","title":"Deye-based 3 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 3 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3K-SG04LP1-EU; catalogue output class 3 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 7 × third-party 550 W panels = 3.85 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-3-2.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048001094,"sku":"DY-PNG-0432","price":37323.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_43e5b737-9d95-42a8-bcee-768cb3f404b3.png?v=1793340323"},{"product_id":"dy-png-0433","title":"Deye-based 3 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 3 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3K-SG04LP1-EU; catalogue output class 3 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-3-3.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048033862,"sku":"DY-PNG-0433","price":28826.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_8f560fed-1200-409c-971c-7dc442284230.png?v=1793340324"},{"product_id":"dy-png-0434","title":"Deye-based 3.6 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 3.6 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3.6K-SG04LP1-EU; catalogue output class 3.6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 8 × third-party 550 W panels = 4.4 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3.6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-3.6-4.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048230470,"sku":"DY-PNG-0434","price":39534.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_4f2c6f0a-946b-4a11-b725-ad2145076f71.png?v=1793340325"},{"product_id":"dy-png-0435","title":"Deye-based 3.6 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 3.6 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3.6K-SG04LP1-EU; catalogue output class 3.6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 8 × third-party 550 W panels = 4.4 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3.6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-3.6-5.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048263238,"sku":"DY-PNG-0435","price":39534.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_5202b0f9-e188-41e5-b9d3-41adaa3e1a76.png?v=1793340326"},{"product_id":"dy-png-0436","title":"Deye-based 3.6 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 3.6 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3.6K-SG04LP1-EU; catalogue output class 3.6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3.6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-3.6-6.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203.6%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%203.6%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048427078,"sku":"DY-PNG-0436","price":29799.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_de226e28-ce8b-452c-8471-65103550dd18.png?v=1793340326"},{"product_id":"dy-png-0437","title":"Deye-based 5 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 5 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-5K-SG04LP1-EU; catalogue output class 5 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 11 × third-party 550 W panels = 6.05 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 5 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-5-7.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048623686,"sku":"DY-PNG-0437","price":45474.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_f4663d39-054b-4227-8b0e-45e7d704cf90.png?v=1793340327"},{"product_id":"dy-png-0438","title":"Deye-based 5 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 5 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-5K-SG04LP1-EU; catalogue output class 5 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 11 × third-party 550 W panels = 6.05 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 5 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-5-8.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048787526,"sku":"DY-PNG-0438","price":45474.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_292a1f40-aae6-4232-a19d-188cac77712a.png?v=1793340328"},{"product_id":"dy-png-0439","title":"Deye-based 5 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 5 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-5K-SG04LP1-EU; catalogue output class 5 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 5 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-5-9.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856048984134,"sku":"DY-PNG-0439","price":32109.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_db156542-ab7f-43f1-a831-66b6872f0cf9.png?v=1793340329"},{"product_id":"dy-png-0440","title":"Deye-based 6 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 6 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-6K-SG04LP1-EU; catalogue output class 6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 14 × third-party 550 W panels = 7.7 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-6-10.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856049180742,"sku":"DY-PNG-0440","price":50771.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_c9a22d02-2c45-4262-8b8d-f01dd3fc43db.png?v=1793340330"},{"product_id":"dy-png-0441","title":"Deye-based 6 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 6 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-6K-SG04LP1-EU; catalogue output class 6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 14 × third-party 550 W panels = 7.7 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-6-11.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856049377350,"sku":"DY-PNG-0441","price":50771.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_88ef00f7-0971-4884-aaa6-4f77929c1b50.png?v=1793340331"},{"product_id":"dy-png-0442","title":"Deye-based 6 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 6 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-6K-SG04LP1-EU; catalogue output class 6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: single-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 2 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 10.24 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 2-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-6-12.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-3-3-6-5-6k-sg04lp1-eu\/\"\u003eSG04LP1 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856049639494,"sku":"DY-PNG-0442","price":33759.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/3-1_6143f67c-a03c-4bed-83ee-f55746165bb4.png?v=1793340331"},{"product_id":"dy-png-0443","title":"Deye-based 8 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 8 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-8K-SG05LP3-EU-SM2; catalogue output class 8 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 18 × third-party 550 W panels = 9.9 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 3 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 15.36 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 8 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 3-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-8-13.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856049770566,"sku":"DY-PNG-0443","price":71528.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_21b55fe1-83ab-4f75-86b3-51ffee506246.png?v=1793340332"},{"product_id":"dy-png-0444","title":"Deye-based 8 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 8 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-8K-SG05LP3-EU-SM2; catalogue output class 8 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 18 × third-party 550 W panels = 9.9 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 3 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 15.36 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 8 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 3-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-8-14.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856049967174,"sku":"DY-PNG-0444","price":71528.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_595f3daf-9145-44d8-b39b-23edef13cdb8.png?v=1793340333"},{"product_id":"dy-png-0445","title":"Deye-based 8 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 8 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-8K-SG05LP3-EU-SM2; catalogue output class 8 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 3 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 15.36 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 8 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 3-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-8-15.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856050163782,"sku":"DY-PNG-0445","price":49632.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_b06a19d4-d41a-4865-8df0-156ba9b512c9.png?v=1793340334"},{"product_id":"dy-png-0446","title":"Deye-based 10 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 10 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-10K-SG05LP3-EU-SM2; catalogue output class 10 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 22 × third-party 550 W panels = 12.1 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 10 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-10-16.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856050294854,"sku":"DY-PNG-0446","price":88622.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_f339f257-1f7d-4121-b7ea-0ca2066629b3.png?v=1793340334"},{"product_id":"dy-png-0447","title":"Deye-based 10 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 10 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-10K-SG05LP3-EU-SM2; catalogue output class 10 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 22 × third-party 550 W panels = 12.1 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 10 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-10-17.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856050458694,"sku":"DY-PNG-0447","price":88622.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_12e86b53-b874-4540-ad0e-969b601393ba.png?v=1793340335"},{"product_id":"dy-png-0448","title":"Deye-based 10 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 10 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-10K-SG05LP3-EU-SM2; catalogue output class 10 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 10 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-10-18.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856050655302,"sku":"DY-PNG-0448","price":61859.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_8aafd049-3900-46bb-bf56-2a04fb5ead02.png?v=1793340336"},{"product_id":"dy-png-0449","title":"Deye-based 12 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 12 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-12K-SG05LP3-EU-SM2; catalogue output class 12 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 27 × third-party 550 W panels = 14.85 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 12 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-12-19.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856050786374,"sku":"DY-PNG-0449","price":98241.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_ec617f99-387e-49ab-9e24-cdeb7992351a.png?v=1793340336"},{"product_id":"dy-png-0450","title":"Deye-based 12 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 12 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-12K-SG05LP3-EU-SM2; catalogue output class 12 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 27 × third-party 550 W panels = 14.85 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 12 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-12-20.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856050917446,"sku":"DY-PNG-0450","price":98241.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_b84a55e5-9e52-41f3-a126-7ab82c6d2155.png?v=1793340337"},{"product_id":"dy-png-0451","title":"Deye-based 12 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 12 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-12K-SG05LP3-EU-SM2; catalogue output class 12 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 4 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 20.48 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 12 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 4-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-12-21.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/www.deyeinverter.com\/product\/three-phase-hybrid-inverter-1\/sun3-4-5-6-8-10-12ksg05lp3eusm2-312kw-three-phase-2-mppt-hybrid-inverter-lv-battery-supported.html\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%2012%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051114054,"sku":"DY-PNG-0451","price":65423.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12_cfac16e1-b1d4-435f-8f05-b57b7637f182.png?v=1793340338"},{"product_id":"dy-png-0452","title":"Deye-based 15 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 15 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-15K-SG05LP3-EU-SM2; catalogue output class 15 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 33 × third-party 550 W panels = 18.15 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 5 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 25.6 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 15 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 5-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-15-22.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-14-15-16-18-20k-sg05lp3-eu-sm2-three-phase-hybrid-inverter\/\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051277894,"sku":"DY-PNG-0452","price":119543.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12-1_13ccc87f-6346-4727-b4f5-ccb85b92198b.png?v=1793340339"},{"product_id":"dy-png-0453","title":"Deye-based 15 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 15 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-15K-SG05LP3-EU-SM2; catalogue output class 15 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 33 × third-party 550 W panels = 18.15 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 5 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 25.6 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 15 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 5-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-15-23.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-14-15-16-18-20k-sg05lp3-eu-sm2-three-phase-hybrid-inverter\/\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051507270,"sku":"DY-PNG-0453","price":119543.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12-1_2bd20bf7-bcd2-4b83-b35b-b5461fb1dc1c.png?v=1793340339"},{"product_id":"dy-png-0454","title":"Deye-based 15 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 15 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-15K-SG05LP3-EU-SM2; catalogue output class 15 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 5 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 25.6 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 15 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 5-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-15-24.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-14-15-16-18-20k-sg05lp3-eu-sm2-three-phase-hybrid-inverter\/\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051638342,"sku":"DY-PNG-0454","price":79415.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12-1_75ad764e-9837-4657-b6a3-4b42ac111e19.png?v=1793340340"},{"product_id":"dy-png-0455","title":"Deye-based 20 kW set - Hybrid solar + battery","description":"\u003ch2\u003eDeye-based 20 kW set - Hybrid solar + battery\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Hybrid solar and battery\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage package designed around selected daytime loads and an assessed backup requirement. Solar generation, battery charging and backup operation depend on the final approved system design. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-20K-SG05LP3-EU-SM2; catalogue output class 20 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 44 × third-party 550 W panels = 24.2 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 7 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 35.84 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime solar generation with stored energy for selected loads. Separating essential from non-essential circuits helps target the available backup capacity.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 20 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 7-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-20-25.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-14-15-16-18-20k-sg05lp3-eu-sm2-three-phase-hybrid-inverter\/\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Hybrid%20solar%20%2B%20battery%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051834950,"sku":"DY-PNG-0455","price":159159.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12-1_426be40e-c552-426b-9e5f-a93c7a6b5c7a.png?v=1793340341"},{"product_id":"dy-png-0456","title":"Deye-based 20 kW set - Off-grid design concept","description":"\u003ch2\u003eDeye-based 20 kW set - Off-grid design concept\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Off-grid design concept\u003c\/p\u003e\u003cp\u003eA proposed solar-and-storage starting configuration for a site requiring power independent of the electricity grid. This is a design concept, not a confirmed all-weather autonomous supply. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-20K-SG05LP3-EU-SM2; catalogue output class 20 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 44 × third-party 550 W panels = 24.2 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 7 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 35.84 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003eCombines daytime generation and storage in one planning concept for remote sites. Load prioritisation and an engineered charging strategy can improve practical resilience.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 20 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 7-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003cli\u003eFor off-grid use, assess daily and seasonal energy demand, local solar resource and required days of autonomy. Include an appropriate contingency charging plan where the assessment requires it. No fixed daily yield or continuous supply is guaranteed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor more daytime energy, assess extra panels and roof\/ground space, then recalculate the complete string layout against the inverter limits. More panels do not automatically increase AC output or guarantee off-grid autonomy.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-20-26.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-14-15-16-18-20k-sg05lp3-eu-sm2-three-phase-hybrid-inverter\/\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential loads\u003c\/strong\u003e: Assess the proposal for selected lighting, communications and other essential loads. Supply peak watts, daily energy and backup hours. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Essential%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Essential%20loads%20profile.%0ATarget%3A%20Assess%20the%20proposal%20for%20selected%20lighting%2C%20communications%20and%20other%20essential%20loads.%20Supply%20peak%20watts%2C%20daily%20energy%20and%20backup%20hours.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended autonomy\u003c\/strong\u003e: Reassess compatible storage AND recharge capacity for actual local solar conditions and required autonomy. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Extended%20autonomy%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Extended%20autonomy%20profile.%0ATarget%3A%20Reassess%20compatible%20storage%20AND%20recharge%20capacity%20for%20actual%20local%20solar%20conditions%20and%20required%20autonomy.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-power loads\u003c\/strong\u003e: Reassess inverter\/phase, battery discharge and starting loads. More panels or battery kWh alone do not raise inverter output. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Off-grid%20design%20concept%20-%20Higher-power%20loads%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Off-grid%20design%20concept%20using%20the%20Higher-power%20loads%20profile.%0ATarget%3A%20Reassess%20inverter%2Fphase%2C%20battery%20discharge%20and%20starting%20loads.%20More%20panels%20or%20battery%20kWh%20alone%20do%20not%20raise%20inverter%20output.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856051966022,"sku":"DY-PNG-0456","price":159159.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12-1_21dc9f27-50a0-4207-8008-d4237dd26ff3.png?v=1793340341"},{"product_id":"dy-png-0457","title":"Deye-based 20 kW set - Battery backup only","description":"\u003ch2\u003eDeye-based 20 kW set - Battery backup only\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Battery backup\u003c\/p\u003e\u003cp\u003eA proposed inverter-and-battery package for selected essential circuits during a supply interruption. No solar panels are included in this configuration; an approved charging source is required. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-20K-SG05LP3-EU-SM2; catalogue output class 20 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC configuration: three-phase inverter family. Confirm the required site voltage\/frequency and, for three-phase installations, each phase’s load and output limit.\u003c\/li\u003e\n\u003cli\u003ePV: no solar panels included. This configuration cannot generate solar energy until an approved PV array is added.\u003c\/li\u003e\n\u003cli\u003eStorage proposal: 7 × Deye SE-G5.1 Pro-B batteries, each LiFePO4, 51.2 V nominal, 100 Ah and 5.12 kWh nominal; total 35.84 kWh nominal. Nominal energy is not guaranteed usable AC energy or runtime. BMS communication and battery\/inverter compatibility must be confirmed.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify battery cables, fuses\/breakers, busbars and communication leads, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePrioritises stored energy for essential circuits without requiring a PV array at the initial stage. Backup duration can be planned around the actual load and usable battery energy.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Do not assume suitability for medical\/life-support or other safety-critical loads without a specialist design.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 20 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eSize the battery bank for BOTH energy and discharge power. Required usable AC energy (kWh) = average backed-up load (kW) × required backup hours. Required nominal battery energy must also allow for permitted depth of discharge, reserve and conversion losses. Confirm that aggregate battery current, BMS limits, inverter limits and cables support the load; the proposed 7-battery bank is not a guaranteed minimum for every application.\u003c\/li\u003e\n\u003cli\u003eAn approved grid or generator charging arrangement is required for ongoing battery-backup operation; confirm charging compatibility and changeover design. Solar is optional and must be engineered if added.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor longer backup time, assess additional compatible battery modules. Each additional SE-G5.1 Pro-B contributes 5.12 kWh nominal, but permissible combinations, firmware, communication, protection and current sharing must be checked. More battery energy does not increase the inverter’s AC output rating.\u003c\/li\u003e\n\u003cli\u003eFor solar charging later, assess compatible panels, mounting, PV protection and the inverter’s MPPT limits before adding an array.\u003c\/li\u003e\n\u003cli\u003eFor higher simultaneous loads, assess a larger inverter or manufacturer-supported parallel design. Do not assume all models can be paralleled or that different inverter models can be mixed. Reassess phase balance, batteries, cabling, protection and charging capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-20-27.\u003c\/p\u003e\u003cp\u003eManufacturer specification references: \u003ca href=\"https:\/\/deye.com\/product\/se-g5-1-pro-b\/\"\u003eSE-G5.1 Pro-B battery\u003c\/a\u003e; \u003ca href=\"https:\/\/deye.com\/product\/sun-14-15-16-18-20k-sg05lp3-eu-sm2-three-phase-hybrid-inverter\/\"\u003eSG05LP3 inverter family\u003c\/a\u003e. Confirm the supplied revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential backup\u003c\/strong\u003e: Assess the listed inverter\/battery proposal against load watts, starting demand and required hours. No PV included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Battery%20backup%20only%20-%20Essential%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Essential%20backup%20profile.%0ATarget%3A%20Assess%20the%20listed%20inverter%2Fbattery%20proposal%20against%20load%20watts%2C%20starting%20demand%20and%20required%20hours.%20No%20PV%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger backup\u003c\/strong\u003e: Request additional compatible storage sized for usable energy AND discharge current within inverter\/BMS limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Battery%20backup%20only%20-%20Longer%20backup%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Longer%20backup%20profile.%0ATarget%3A%20Request%20additional%20compatible%20storage%20sized%20for%20usable%20energy%20AND%20discharge%20current%20within%20inverter%2FBMS%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd solar charging\u003c\/strong\u003e: Request a compatible PV array, string design, mounting, cables, protection and installation. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20set%20-%20Battery%20backup%20only%20-%20Add%20solar%20charging%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20set%20-%20Battery%20backup%20only%20using%20the%20Add%20solar%20charging%20profile.%0ATarget%3A%20Request%20a%20compatible%20PV%20array%2C%20string%20design%2C%20mounting%2C%20cables%2C%20protection%20and%20installation.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856052162630,"sku":"DY-PNG-0457","price":105650.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/12-1_86c7c14d-8e5d-4dc0-8aae-63db303de872.png?v=1793340342"},{"product_id":"dy-png-0458","title":"Deye-based 3 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 3 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-3K-G04P1-EU-AM1; catalogue output class 3 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 7 × third-party 550 W panels = 3.85 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 3 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-3.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%203%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%203%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856052359238,"sku":"DY-PNG-0458","price":15758.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/6_6386cc1e-e899-4324-a82f-859848e4f32a.png?v=1793340343"},{"product_id":"dy-png-0459","title":"Deye-based 5 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 5 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-5K-G06P3-EU-BM2; catalogue output class 5 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 11 × third-party 550 W panels = 6.05 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 5 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-5.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%205%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%205%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856052555846,"sku":"DY-PNG-0459","price":22506.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/1-1_bd7ed5d5-8199-4efd-9b93-405ad9b52f36.png?v=1793340344"},{"product_id":"dy-png-0460","title":"Deye-based 6 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 6 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-6K-G06P3-EU-BM2; catalogue output class 6 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 14 × third-party 550 W panels = 7.7 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 6 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-6.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%206%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%206%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856052621382,"sku":"DY-PNG-0460","price":27093.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/1-1_4fa3b7ef-7407-407a-93e8-755f3c608231.png?v=1793340344"},{"product_id":"dy-png-0461","title":"Deye-based 8 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 8 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-8K-G06P3-EU-BM2; catalogue output class 8 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 18 × third-party 550 W panels = 9.9 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 8 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-8.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%208%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%208%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856052817990,"sku":"DY-PNG-0461","price":33842.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/1-1_6210d613-1cde-4ad0-8f84-a21a1f945158.png?v=1793340345"},{"product_id":"dy-png-0462","title":"Deye-based 10 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 10 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eResidential catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-10K-G06P3-EU-BM2; catalogue output class 10 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 22 × third-party 550 W panels = 12.1 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed household essential circuits such as lighting, communications, computers and selected refrigeration. Appliance names are examples, not a promise that every appliance can operate together. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 10 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-10.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2010%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%2010%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856052981830,"sku":"DY-PNG-0462","price":40574.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/1-1_8499587f-9d20-434c-b03f-d090479b959f.png?v=1793340345"},{"product_id":"dy-png-0463","title":"Deye-based 15 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 15 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-15K-G06P3-EU-BM2; catalogue output class 15 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 33 × third-party 550 W panels = 18.15 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 15 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-15.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2015%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%2015%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856053112902,"sku":"DY-PNG-0463","price":58641.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/1-1_7d7800e9-8123-4f54-ac69-88dd7b4c2694.png?v=1793340346"},{"product_id":"dy-png-0464","title":"Deye-based 20 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 20 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-20K-G05; catalogue output class 20 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 44 × third-party 550 W panels = 24.2 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 20 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-20.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2020%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%2020%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856053211206,"sku":"DY-PNG-0464","price":76725.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/6-1_37685551-a5b6-471f-9636-eafa1b8b29a5.png?v=1793340347"},{"product_id":"dy-png-0465","title":"Deye-based 30 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 30 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-30K-G04; catalogue output class 30 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 66 × third-party 550 W panels = 36.3 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 30 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-30.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2030%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%2030%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2030%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%2030%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2030%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%2030%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856053375046,"sku":"DY-PNG-0465","price":112860.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/7_0fa5ee16-d743-491c-b4f0-c4f344b8cfc4.png?v=1793340348"},{"product_id":"dy-png-0466","title":"Deye-based 50 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 50 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-50K-G04; catalogue output class 50 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 110 × third-party 550 W panels = 60.5 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 50 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-50.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2050%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%2050%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2050%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%2050%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2050%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%2050%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856053538886,"sku":"DY-PNG-0466","price":185147.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/8-1_2a2f02ee-72ce-47f5-a012-0e006f29e7e4.png?v=1793340348"},{"product_id":"dy-png-0467","title":"Deye-based 80 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 80 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-80K-G04P3-EU-AM4; catalogue output class 80 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 175 × third-party 550 W panels = 96.25 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 80 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-80.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2080%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%2080%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2080%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%2080%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%2080%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%2080%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856053702726,"sku":"DY-PNG-0467","price":292347.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/9_8d2c1b5c-a55b-4c77-9594-4c53a13f62d6.png?v=1793340349"},{"product_id":"dy-png-0468","title":"Deye-based 100 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 100 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-100K-G03; catalogue output class 100 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 219 × third-party 550 W panels = 120.45 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 100 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-100.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%20100%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%20100%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%20100%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%20100%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%20100%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%20100%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856053899334,"sku":"DY-PNG-0468","price":364634.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/10_51d2bfe9-070a-44e7-a1c4-65687c8bdcac.png?v=1793340350"},{"product_id":"dy-png-0469","title":"Deye-based 125 kW on-grid PV set","description":"\u003ch2\u003eDeye-based 125 kW on-grid PV set\u003c\/h2\u003e\u003cp\u003eIndustrial catalogue range · Grid-connected solar\u003c\/p\u003e\u003cp\u003eA proposed solar-generation package for a site with an available grid connection and suitable daytime electricity demand. It is intended to offset some purchased electricity, not provide power during a blackout. Proposed reseller configuration, not a factory Deye kit. Final equipment, compatibility and quantities require a written quotation and engineering assessment.\u003c\/p\u003e\u003ch3\u003eProposed specifications and contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInverter proposal: 1 × Deye SUN-125K-G01P3-EU-AM8; catalogue output class 125 kW. Confirm the exact nameplate, operating conditions and AC output limits before selection; backup and surge ratings apply only where supported by that model.\u003c\/li\u003e\n\u003cli\u003eAC phase, voltage, frequency, MPPT limits and connection settings: confirm against the exact inverter datasheet and site supply.\u003c\/li\u003e\n\u003cli\u003ePV proposal: 273 × third-party 550 W panels = 150.15 kWp nameplate array capacity. Panel manufacturer\/model is not selected; voltage, current, dimensions and string layout remain unconfirmed. This is a proposed quantity, not a validated minimum string size.\u003c\/li\u003e\n\u003cli\u003eStorage: no battery included. This grid-only set does not provide blackout backup.\u003c\/li\u003e\n\u003cli\u003eBalance of system (BOS): allowance only, not a confirmed itemised supply list. Final design must identify mounting rails\/clamps, PV cabling\/connectors and DC isolation\/protection, AC isolation\/protection, earthing and any required metering\/monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBenefits and intended use\u003c\/h3\u003e\u003cp\u003ePotentially reduces daytime grid purchases when solar production coincides with consumption. Actual savings depend on shading, weather, operating hours and approved connection arrangements.\u003c\/p\u003e\u003cp\u003eConsider for assessed business or industrial essential circuits such as office systems, communications, lighting and selected refrigeration or process-support loads. Heavy machinery, pumps, compressors and motors require separate starting-current and phase assessment. Not suitable as a stand-alone off-grid or outage-backup supply.\u003c\/p\u003e\u003ch3\u003eMinimum requirements before ordering\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvide an appliance\/load schedule with watts, operating hours, simultaneous demand and motor starting loads. For backup\/off-grid operation, inverter continuous and surge output must cover the selected loads within model and per-phase limits. For grid-only operation, size solar to daytime demand and the approved connection capacity; 125 kW is not a promise of whole-site coverage.\u003c\/li\u003e\n\u003cli\u003eProvide a suitable grid connection and site assessment. Verify connection\/export arrangements and protection settings with the installer and relevant network operator. No grid-independent supply is provided.\u003c\/li\u003e\n\u003cli\u003eDetermine the minimum panels per string using the selected panel’s temperature-adjusted voltage, inverter start-up voltage and MPPT operating window. Check maximum cold-weather open-circuit voltage, operating\/short-circuit current and permitted PV power before fixing series\/parallel quantities. Array kWp alone does not establish compatibility.\u003c\/li\u003e\n\u003cli\u003eA qualified installer must verify structural support, shading and PV mounting, equipment environment, ventilation, protection, earthing, safe isolation and commissioning. Do not install or expand from this catalogue description alone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eExpansion to match your requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor higher daytime generation, consider extra panels only within the existing inverter’s verified PV voltage, current, power and MPPT limits. Additional inverter capacity requires a revised site\/network design.\u003c\/li\u003e\n\u003cli\u003eFor blackout backup, obtain a redesigned storage-capable system or an engineered compatible retrofit. Adding a battery alone does not convert this grid-only inverter into a backup system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuotation and exclusions\u003c\/h3\u003e\u003cp\u003eFor sizing, provide your location, supply phase, appliance list, daily use, required backup hours, existing equipment and future expansion plans. Contact sales@solitecpng.com or +675 70868277.\u003c\/p\u003e\u003cp\u003eCatalogue set reference: SET-ONGRID-125.\u003c\/p\u003e\n\u003ch3\u003eChoose a proposed configuration for quotation\u003c\/h3\u003e\u003cp\u003eThese are planning targets, not installed specifications or guaranteed model options. Each link opens an email enquiry, not a priced checkout configuration. Solitec must validate the final bill of materials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaytime generation\u003c\/strong\u003e: Assess the existing array proposal against daytime energy use, shading and network settings. No battery or blackout backup included. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%20125%20kW%20on-grid%20PV%20set%20-%20Daytime%20generation%20configuration\u0026amp;body=Please%20quote%20Deye-based%20125%20kW%20on-grid%20PV%20set%20using%20the%20Daytime%20generation%20profile.%0ATarget%3A%20Assess%20the%20existing%20array%20proposal%20against%20daytime%20energy%20use%2C%20shading%20and%20network%20settings.%20No%20battery%20or%20blackout%20backup%20included.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher daytime demand\u003c\/strong\u003e: Request a revised array\/inverter design within verified voltage, current, MPPT and power limits. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%20125%20kW%20on-grid%20PV%20set%20-%20Higher%20daytime%20demand%20configuration\u0026amp;body=Please%20quote%20Deye-based%20125%20kW%20on-grid%20PV%20set%20using%20the%20Higher%20daytime%20demand%20profile.%0ATarget%3A%20Request%20a%20revised%20array%2Finverter%20design%20within%20verified%20voltage%2C%20current%2C%20MPPT%20and%20power%20limits.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup required\u003c\/strong\u003e: Request a storage-capable redesign or approved retrofit; a battery alone does not make this grid-only set a backup supply. \u003ca href=\"mailto:sales@solitecpng.com?subject=Deye-based%20125%20kW%20on-grid%20PV%20set%20-%20Backup%20required%20configuration\u0026amp;body=Please%20quote%20Deye-based%20125%20kW%20on-grid%20PV%20set%20using%20the%20Backup%20required%20profile.%0ATarget%3A%20Request%20a%20storage-capable%20redesign%20or%20approved%20retrofit%3B%20a%20battery%20alone%20does%20not%20make%20this%20grid-only%20set%20a%20backup%20supply.%0AQuantity%3A%0ALocation%3A%0AApplications%20%2F%20load%3A%0ARequired%20date%3A%0APlease%20confirm%20compatibility%20and%20total%20price.\"\u003eRequest this profile by email\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Solitec","offers":[{"title":"Default Title","offer_id":50856054063174,"sku":"DY-PNG-0469","price":453767.0,"currency_code":"PGK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/8050\/4646\/files\/11-1_5562ba58-ca63-4810-bb8e-70adb3d61e44.png?v=1793340351"}],"url":"https:\/\/xrosia-pg.com\/collections\/solar-kits.oembed?page=2","provider":"Solitec PNG","version":"1.0","type":"link"}